Over 15 years of experience
Specialist Hydrogen Tracer Gas Leak Detection in London
A hidden water leak can remain undetected for weeks or months, particularly when the damaged pipe is buried beneath flooring or concealed inside a wall. Customers may notice unexplained water bills, continuous water meter movement, repeated central heating pressure loss, damp patches or moisture appearing around a concrete floor.
When we attend a property, we first investigate which plumbing or heating system could be responsible. A leaking incoming mains water supply, central heating return pipe and underfloor heating circuit each require different preparation and testing procedures. We examine accessible pipework, isolation valves, pressure gauges and the likely route of concealed pipes before deciding how to proceed.
Hydrogen tracer gas testing is particularly useful where conventional acoustic leak detection, thermal imaging or visual inspection cannot provide sufficient evidence. Our objective is to establish a reliable suspected leak location before recommending access or repair work.
How Hydrogen Leak Detection Works
Hydrogen tracer gas leak detection involves introducing a suitable test gas into an isolated pipe circuit and using sensitive electronic equipment to identify where gas escapes through a defect.
The test mixture contains 5% hydrogen and 95% nitrogen, commonly called forming gas. Hydrogen’s small molecular size allows it to escape through small openings in pipework, while specialist hydrogen sensors can detect low concentrations reaching accessible surfaces.
When a leak occurs beneath concrete, screed, insulation or soil, the escaping gas may travel through surrounding materials before reaching the detector. This makes tracer gas useful for investigating concealed pipe defects, although the highest reading does not necessarily identify the exact position of the damaged pipe.
1
Plumbing System Assessment
We assess the reported leak symptoms, check accessible plumbing connections and review water meter or pressure readings where appropriate. This helps identify the suspected pipe circuit and determine whether hydrogen tracer gas testing is suitable.
2
Pipe Isolation and Preparation
We identify and isolate the affected water supply, central heating or underfloor heating circuit where possible. The pipework is prepared for controlled tracer gas testing, with suitable connections and test pressures selected for the installation.
3
Hydrogen Tracer Gas Testing
We introduce a specialist 5% hydrogen and 95% nitrogen forming-gas mixture into the prepared pipework. Sensitive electronic hydrogen detectors are then used to investigate suspected leaks beneath concrete, screed, flooring or underground.
4
Leak Location Assessment
We compare hydrogen sensor readings along the suspected pipe route and assess possible gas migration through cracks, insulation or underground voids. Where necessary, we use pressure testing, acoustic detection or thermal imaging to support our findings.
5
Report and Repair Recommendations
We explain the investigation results and provide an insurance-ready photographic report documenting the evidence and any limitations. If a leak is identified, we recommend targeted access and provide a separate quotation for the necessary repair work.
How we found hidden water leaks without damaging your home
Hydrogen Leak Detection for Central Heating Systems
A sealed central heating system that repeatedly loses pressure may have a concealed pipe leak, but pressure loss does not automatically mean the pipework is damaged. Faults involving expansion vessels, pressure relief valves, radiator connections or other heating components can produce similar symptoms.
We assess accessible components and system behaviour before testing concealed heating pipes. Where a hidden leak remains suspected, hydrogen tracer gas can help investigate heating flow and return pipes beneath timber floors, concrete slabs or screed.
The method can be particularly useful for small leaks that only become apparent through repeated pressure loss. Read our boiler losing pressure FAQ for a more detailed explanation of possible causes.
Underfloor Heating Leak Detection Using Hydrogen Gas
Underfloor heating systems contain pipe loops connected to a manifold, often installed beneath screed, tiles, engineered timber or other finished flooring. A leak in one circuit may cause pressure loss without any obvious surface water.
Before introducing tracer gas, we examine the underfloor heating manifold, accessible connections and isolation arrangements. Individual loops may be tested where the system configuration allows.
Hydrogen readings can help narrow down a suspected pipe defect, reducing the need to remove large areas of flooring without evidence. However, gas migration through insulation, expansion joints and floor construction can affect where the strongest readings appear.
Underground Water Supply and MDPE Pipe Leak Detection
Underground water supply leaks may occur in MDPE, copper or other buried pipework running beneath gardens, driveways, patios, paving and concrete surfaces.
Common symptoms include unusually high water bills, a water meter moving when all outlets are closed, unexplained ground moisture or reduced water pressure.
Where the affected supply can be appropriately isolated, hydrogen tracer gas may help investigate a concealed underground defect. The detector is used to check accessible ground surfaces and suspected pipe routes for escaping gas.
Soil composition, pipe depth, ground saturation, buried services and surface coverings can all influence how gas travels. We assess these conditions before recommending excavation.
Detecting Leaks Beneath Concrete and Screed Floors
A leaking pipe beneath a concrete slab can allow water to spread through insulation, screed, joints and adjacent construction before becoming visible. The resulting damp patch may be some distance from the original pipe defect.
Hydrogen tracer gas testing can help investigate concealed pressurised pipes beneath concrete or tiled floors without immediately breaking up the surface.
We consider the suspected pipe route, floor construction, moisture distribution and repeatability of hydrogen readings. If a location cannot be established confidently, we explain the remaining uncertainty rather than recommending unnecessary demolition.


Can Hydrogen Detect Very Small Pipe Leaks?
Hydrogen tracer gas can be useful for investigating small defects in pressurised pipework, including leaks that produce limited noise or little visible water damage.
The ability to detect escaping gas depends on the leak opening, test conditions, detector sensitivity and the surrounding materials. A very small leak may still be difficult to locate if gas cannot reach an accessible sampling point.
For this reason, we do not advertise a universal minimum leak size or guaranteed detection accuracy. We assess the evidence obtained from the actual installation.
How We Choose the Right Leak Detection Method for Concealed Pipework
Finding a hidden pipe leak requires more than selecting one piece of equipment. Different plumbing systems, pipe materials and building structures produce different diagnostic evidence. When we investigate a suspected leak beneath concrete, screed or flooring, we assess the system’s pressure behaviour, the likely pipe route and the surrounding construction before deciding which tests will provide the most useful information.
Acoustic leak detection helps us investigate the sound and vibration produced by escaping water in pressurised pipes. However, plastic pipework, low water pressure, thick concrete and background noise can make small leaks difficult to hear. Where acoustic readings are inconclusive, we consider whether hydrogen tracer gas testing could provide additional evidence.
Thermal imaging helps us identify temperature differences associated with heating pipes, hot water circulation and moisture-affected surfaces. It can reveal useful patterns beneath flooring or across walls, but a thermal camera cannot see directly through concrete. We interpret these temperature patterns alongside other observations rather than treating them as confirmation of a pipe leak.
Moisture mapping allows us to assess how water has spread through floors, walls and surrounding building materials. A damp patch does not always appear directly above the damaged pipe, particularly where water has travelled beneath screed or along insulation. Moisture readings help us understand the affected area but cannot independently establish the source.
Hydrogen tracer gas testing provides a different type of evidence by detecting gas escaping from a prepared, isolated pipe circuit. This can be particularly valuable when investigating concealed central heating pipes, underfloor heating loops and underground water supplies where other methods have not established a reliable suspected leak location.
At MML Plumbing Ltd, we combine practical plumbing knowledge with appropriate diagnostic methods to build a clearer picture of the problem. We aim to establish the most likely leak location, explain the supporting evidence and recommend targeted access only when the findings justify it. This approach helps reduce unnecessary damage while giving homeowners and property managers a clearer basis for repair decisions.

Why Hydrogen Readings Require Professional Interpretation
An electronic hydrogen detector measures gas concentration at its sampling point, often expressed in parts per million (ppm). It does not directly measure the size of a leak or the distance to the damaged pipe.
Escaping gas can travel along insulation, through cracks in concrete, around service penetrations or through underground voids. This means a surface reading may be displaced from the actual pipe defect.
When interpreting results, we consider the pipe route, system pressure, construction materials, repeated readings and any supporting evidence from other diagnostic tests.
The purpose is to establish a defensible conclusion before recommending targeted access.
Can Hydrogen Tracer Gas Rule Out Hidden Heating Leaks When a Radiator Stays Cold?
A radiator that remains cold while other radiators heat normally does not necessarily indicate a hidden pipe leak. During our leak detection and heating system investigation in N11, North London, we investigated a living room radiator that was failing to heat properly. Hydrogen tracer gas testing found no evidence of leakage in the investigated heating pipework, while thermal imaging revealed restricted hot water circulation and cold areas consistent with sludge accumulation. Further checks showed that the heating system was incorrectly balanced, with hot water favouring other radiators. We adjusted the lockshield valves and flushed the affected radiator, restoring circulation. Follow-up temperature readings reached 64°C at the top and 56°C at the bottom, confirming improved heating performance without unnecessary pipe replacement or floor excavation.

Professional Hydrogen Leak Detection Equipment
We use specialist hydrogen detection equipment designed to identify tracer gas concentrations at accessible sampling points.
The investigation may involve electronic hydrogen sensors, sampling probes, controlled gas supply equipment and pressure-monitoring instruments. The precise setup depends on the affected pipe system and the testing conditions.
Professional equipment is important, but accurate interpretation is equally essential. Our engineers assess sensor readings alongside plumbing system knowledge, pipe routing and construction details to determine the most appropriate next step.
Our Professional Qualifications and Certifications
Plumbing & Water Systems
- City & Guilds NVQ Level 2 in Plumbing
- NVQ Level 3 Diploma in Plumbing & Heating
- WRAS Approved – Water Regulations Compliance
- G3 – Unvented & Vented Hot Water Systems
- WaterSafe Approved Contractor
Specialist Leak Detection
- Acoustic Leak Detection – Pressurised & Buried Pipe Systems
- Hydrogen Tracer Gas Leak Detection (Non-Invasive)
- ITC Certified Thermal Imaging Diagnostics
- Moisture Mapping & Damp Investigation
- Insurance-Ready Trace & Access Reporting
- IICRC Certified – Water Damage Inspection Standards
System & Technical Experience
- Central Heating & Underfloor Heating Leak Investigation
- Mains Water Supply & Underground Pipe Diagnostics
- Domestic & Commercial Plumbing Systems
- Vented & Unvented Hot Water Systems
- Water & Sewage Utility Plumbing
Hydrogen Leak Detection Cost in London
Our standard domestic non-invasive leak detection investigation costs £550 + VAT, including the call-out and an insurance-ready photographic report.
Hydrogen tracer gas testing is used where appropriate for the suspected pipework and investigation scope. Complex heating installations, multiple independent pipe circuits, larger commercial properties and extensive underground systems may require an individually prepared quotation.
The investigation covers diagnostic work and reporting. Any subsequent excavation, floor opening, pipe repair or reinstatement is quoted separately once the source and recommended repair method have been established.
For additional pricing information, visit our plumbing and heating prices.

Insurance-Ready Hydrogen Leak Detection Reports
Every investigation is documented to explain what was reported, which systems were examined and what the diagnostic evidence indicates.
Depending on the work undertaken, the report may include pressure readings, testing durations, hydrogen detector observations, thermal images, moisture readings and photographs of accessible pipework or affected areas.
We distinguish between confirmed findings, suspected defects and any limitations that remain. This helps homeowners, landlords, managing agents and insurers understand the investigation and the recommended next steps.
Our reports are prepared to support insurance Trace & Access enquiries where relevant, although cover and claim acceptance depend on the customer’s policy and insurer.
If a repair is required, we can provide a separate quotation for the appropriate water leakage repair work.
Hydrogen Tracer Gas Safety and Testing Conditions
Hydrogen tracer gas testing uses a dilute hydrogen–nitrogen mixture introduced into suitable pipework under controlled conditions.
Before testing, we assess the system’s condition, isolation arrangements, connections and appropriate test pressure. The testing procedure is selected according to the installation and the manufacturer’s equipment guidance.
MML Plumbing Ltd carries £2 million public liability insurance. Our engineers explain any relevant limitations before work proceeds, including situations where further testing or controlled access may be necessary.

Book Hydrogen Leak Detection in London
If you suspect a hidden water leak beneath a concrete floor, within an underfloor heating circuit or along an underground water supply, MML Plumbing can investigate the symptoms and determine whether hydrogen tracer gas testing is suitable.
We use practical plumbing knowledge and specialist diagnostic equipment to gather evidence before recommending unnecessary opening-up work.
Call us to discuss your suspected leak and arrange an investigation.
For alternative diagnostic methods, see our acoustic leak detection, thermal imaging leak detection, moisture leak detection and borescope leak detection services.
How Hydrogen Tracer Gas Testing Fits Into a Leak Investigation
Hydrogen tracer gas testing is one of several methods we use to investigate concealed water leaks across London. At MML Plumbing Ltd, we select the appropriate diagnostic technique after assessing the suspected pipework, the symptoms and the construction of the property. Our aim is to establish reliable evidence before recommending unnecessary excavation or opening up floors and walls.
Hydrogen testing is particularly useful for investigating suspected leaks in central heating pipes, underfloor heating circuits, buried MDPE water supplies and pressurised plumbing systems. Where required, we combine tracer gas readings with pressure testing, acoustic detection, thermal imaging or moisture mapping to support our findings.
Hydrogen Tracer Gas Compared With Other Leak Detection Methods
| Detection Method | When We Use It |
|---|---|
| Hydrogen Tracer Gas Detection | Our specialist method for investigating suspected defects in isolated, pressurised pipework beneath concrete, screed, flooring or underground. A 5% hydrogen and 95% nitrogen test mixture is monitored using sensitive electronic detectors to help narrow down the suspected leak location. |
| Acoustic Leak Detection | Uses sensitive listening equipment to investigate sound and vibration from escaping water in suitable pressurised pipes. Results depend on pipe material, water pressure, surrounding construction and background noise. |
| Thermal Imaging | Identifies surface temperature differences that may help trace concealed heating pipes, underfloor heating circuits or moisture-related thermal patterns. Thermal cameras do not see directly through walls or concrete. |
| Moisture Mapping | Measures moisture patterns in walls, ceilings and floors to assess the extent of water movement. Useful for distinguishing affected areas and supporting an investigation, although moisture readings alone do not confirm the source. |
| Borescope Inspection | Uses a small inspection camera to examine accessible concealed spaces, floor voids and pipe connections through existing openings or limited access points. |
| Water Meter & Pressure Testing | Helps establish whether a water supply or isolated heating circuit is losing water or pressure. These checks can guide the investigation before specialist hydrogen tracer gas testing is considered. |
Which method is right for your leak? Not every concealed leak requires hydrogen testing. Our engineers assess the installation and select the most appropriate method for the evidence available. For investigations covering a wider range of water leak problems, see our professional leak detection services in London.
Suspected leaks in underground or external water supply pipes may also require specialist mains water leak detection, depending on the pipe route and site conditions.
Following the investigation, we provide an insurance-ready photographic report documenting the tests undertaken, relevant readings, findings and recommended next steps. Any necessary repair work is quoted separately.
Need hydrogen leak detection in London?
Call 020 8355 0840
or request an investigation online.
We Find the Leak Before It Finds You – Book Expert Detection Today
Frequently Asked Questions About Hydrogen Leak Detection
Question not answered? Ask A Question
What is hydrogen leak detection used for, and when should I book a tracer gas investigation?
Hydrogen leak detection is a specialist method used to investigate hidden water leaks in concealed, pressurised pipework, particularly when the suspected leak cannot be seen or reliably located through conventional inspection. In London properties, we commonly consider hydrogen tracer gas testing for central heating pipes beneath floors, underfloor heating circuits embedded in screed, underground water supplies and concealed hot or cold water pipework.
Typical warning signs include a central heating system that repeatedly loses pressure, a water meter that continues moving when all outlets are closed, unusually high water bills, unexplained damp patches or moisture appearing around concrete floors. These symptoms can indicate a concealed leak, although other plumbing faults must also be considered.
At MML Plumbing Ltd, we begin by assessing the affected plumbing or heating system. We may carry out pressure monitoring, water meter checks, inspection of accessible connections and other diagnostic tests before deciding whether hydrogen is suitable. Where appropriate, a controlled mixture of 5% hydrogen and 95% nitrogen is introduced into isolated pipework, and electronic sensors are used to investigate escaping gas.
The purpose is to gather evidence of the suspected leak location and reduce unnecessary opening-up work. Not every water leak requires tracer gas testing, and we select the investigation method according to the installation and symptoms. For a broader explanation of heating pressure problems, see our boiler losing pressure FAQ.
Can hydrogen leak detection locate water leaks beneath concrete floors, screed, tiles and underground pipes?
Hydrogen tracer gas can help locate suspected leaks in pressurised pipes concealed beneath concrete slabs, floor screed, tiles, timber flooring and underground surfaces. This makes it particularly useful where a pipe defect is suspected, but the property owner wants to avoid breaking up large sections of flooring without reliable evidence.
During testing, we introduce a suitable hydrogen–nitrogen tracer gas mixture into an isolated pipe circuit. If a defect is present, gas may escape through the damaged section and travel through surrounding materials. Our electronic hydrogen detectors are used to investigate accessible surfaces, floor joints, service penetrations and suspected pipe routes.
However, hydrogen does not always emerge directly above the damaged pipe. Gas can migrate along insulation, through cracks in concrete, beneath membranes or through underground voids. Soil conditions, water saturation, pipe depth and floor construction may also influence the readings.
For this reason, we interpret hydrogen readings alongside the likely pipe route, pressure test results, moisture distribution and other diagnostic evidence. Where the results support a suspected location, we can recommend targeted access rather than unnecessary exploratory excavation. If the evidence remains inconclusive, we explain the limitations and whether further investigation is required.
Can hydrogen tracer gas find underfloor heating leaks when the system keeps losing pressure?
Hydrogen tracer gas testing can be effective for investigating concealed underfloor heating leaks, particularly when a sealed heating system repeatedly loses pressure, but there is no visible water damage. Underfloor heating pipes are often embedded beneath screed, tiles or other finished flooring, making direct inspection difficult without removing part of the floor.
Before testing, we examine the underfloor heating manifold, isolation valves, pipe connections and pressure behaviour. A pressure drop does not automatically mean that an underfloor heating pipe has failed. Leaking manifold connections, radiator fittings, expansion vessel problems and pressure relief valve faults can produce similar symptoms.
Where the evidence indicates a possible concealed pipe defect, we assess whether individual underfloor heating loops can be isolated and tested. Hydrogen tracer gas may then be introduced into the prepared circuit, with electronic detectors used to investigate the suspected pipe route beneath the floor.
The results depend on the construction of the floor, the pipe layout, the condition of the circuit and how the gas travels through surrounding materials. Our objective is to narrow down the suspected leak location before recommending access or repairs, rather than removing large sections of flooring based on pressure loss alone.
Does a heating system need to be drained before hydrogen tracer gas leak detection?
Hydrogen tracer gas testing may require a central heating or underfloor heating circuit to be partially or fully drained, depending on the installation, the testing equipment and the section of pipework being investigated. The preparation must be appropriate for the system rather than following the same procedure at every property.
When we attend, we first assess the heating system configuration, accessible isolation valves, manifolds, filling arrangements and any components that could be affected by testing. We also consider the manufacturer’s requirements and the appropriate test pressure for the pipework.
Where necessary, the affected circuit is isolated and prepared so that tracer gas can be introduced under controlled conditions. In properties with multiple heating zones or complex underfloor heating installations, individual circuits may need separate assessment or testing.
Following the investigation, the relevant system may require refilling, venting, pressure checks and recommissioning, depending on the work undertaken and whether any defects remain. We explain the proposed testing procedure and any additional work before proceeding.
For London homeowners experiencing repeated heating pressure loss, the important first step is establishing whether the problem originates from concealed pipework or an accessible heating component. Hydrogen testing is a diagnostic option, not an automatic requirement for every pressure-loss problem.
Is hydrogen leak detection safe inside occupied homes, flats and commercial buildings?
Professional hydrogen tracer gas leak detection uses a dilute forming-gas mixture, commonly containing 5% hydrogen and 95% nitrogen. This mixture is used in suitable leak detection applications because sensitive electronic equipment can detect hydrogen escaping from defects in prepared pipework.
Before testing, we assess the condition of the plumbing or heating system, available isolation points, connections, ventilation considerations and appropriate test pressures. The procedure must be carried out using suitable equipment and in accordance with relevant safety precautions and manufacturer guidance.
Hydrogen testing may be considered in occupied houses, converted flats, apartment buildings and commercial premises, provided the installation and testing conditions are suitable. However, access arrangements, shared services, complex heating systems or restrictions on isolation can affect whether the method is appropriate.
At MML Plumbing Ltd, we explain the intended investigation and any relevant limitations before introducing tracer gas. We do not assume that every pipe circuit can be safely isolated or tested in the same way.
Where hydrogen testing is unsuitable, we may recommend alternative diagnostic methods such as pressure monitoring, acoustic leak detection, thermal imaging or moisture mapping to investigate the suspected source of water loss.
How much does hydrogen leak detection cost in London, and what happens after the investigation?
At MML Plumbing Ltd, our standard domestic non-invasive leak detection investigation costs £550 + VAT. This includes the call-out, diagnostic investigation and an insurance-ready photographic report. Hydrogen tracer gas testing is selected where appropriate to the suspected pipework and agreed investigation scope.
More complex investigations may require a separate quotation. These can include commercial heating installations, multiple independent underfloor heating circuits, extensive underground pipework or systems requiring substantial preparation and isolation before testing.
During the investigation, we assess the reported symptoms and carry out the diagnostic procedures appropriate to the installation. Where hydrogen tracer gas testing is undertaken, we evaluate detector readings alongside the suspected pipe route, pressure behaviour and any supporting evidence from other tests.
Afterwards, we provide a written photographic leak detection report explaining the systems examined, relevant test observations, findings, limitations and recommended next steps. The report can support insurance Trace & Access enquiries where relevant, although insurance cover and claim acceptance depend on the individual policy and insurer.
If a concealed pipe leak is identified or strongly suspected, we explain the recommended access and repair options. Any floor opening, excavation, pipe replacement, reinstatement or additional remedial work is quoted separately, allowing you to review the investigation evidence before authorising repairs.
To discuss a suspected hidden heating or water supply leak in London, call 020 8355 0840 and explain the symptoms, affected system and property type so we can advise on the appropriate investigation.