Can Hydrogen Detection Find Very Small Leaks?

Yes. Hydrogen tracer gas detection can identify very small leaks, including micro-leaks in concealed plumbing and heating pipes that produce little or no visible water damage, detectable sound or temperature change. This specialist leak detection method uses a tracer gas mixture, typically 95% nitrogen and 5% hydrogen, together with high-sensitivity sensors to investigate small defects in pressurised pipework.

Hydrogen molecules are extremely small and can escape through fine cracks, corrosion pinholes and deteriorated pipe connections. When the tracer gas reaches an accessible sampling point, specialist hydrogen detection equipment measures its concentration in parts per million (ppm).

However, detecting a low hydrogen concentration is not the same as measuring the size of a water leak. The accuracy of the investigation depends on the detection systems, test pressure, pipe material, surrounding construction, gas migration and the engineer’s interpretation.

Hydrogen gas is colourless, odourless and tasteless, so its presence cannot be reliably identified through human senses. Professional hydrogen detection therefore relies on calibrated sensors rather than smell, sound or visual observation.

    Not Sure What’s Causing the Problem? We Find the Cause — Then Fix It


    From hidden leaks to plumbing and heating issues, tell us what’s happening
    and we’ll assess it properly, explain your options, and get it sorted.

    Why Hydrogen Molecules Can Reveal Microscopic Pipe Defects

    Hydrogen is the lightest chemical element, and molecular hydrogen (H₂) has a very small molecular size.

    These hydrogen properties make it useful for specialist tracer gas applications because hydrogen can pass through small openings and disperse through suitable surrounding materials.

    However, the effectiveness of hydrogen detection depends on more than molecular size.

    Three physical characteristics are particularly important when identifying small leaks.

    1. Small Molecular Size and Pipe Defects

    Hydrogen molecules can escape through fine openings in pipework when an appropriate pressure difference exists.

    These defects may include early-stage corrosion pinholes, hairline fractures in copper pipes, small cracks in plastic pipework, deteriorated soldered joints and compression fittings that no longer seal correctly.

    A defect may release only a small amount of water during normal operation.

    When the system is isolated and pressurised using an appropriate tracer gas mixture, hydrogen may escape through the same opening and become detectable.

    However, water and gas behave differently.

    Water has different viscosity, surface tension and flow characteristics. A defect that permits tracer gas to escape does not necessarily release water at an equivalent rate.

    Therefore, hydrogen detection results must be interpreted alongside the operating pressure and condition of the plumbing system.

    2. Hydrogen Mobility and Gas Migration

    Hydrogen has a much lower density than air and can disperse rapidly when released.

    In concealed plumbing investigations, escaping tracer gas may migrate through soil, cracks in concrete, construction joints, screed, cavities and gaps around pipe penetrations.

    This movement can allow hydrogen to reach accessible surfaces even when the damaged pipe is concealed.

    For example, a small leak beneath a concrete floor may produce a measurable hydrogen concentration at a nearby expansion joint.

    However, gas migration does not always follow a direct vertical route.

    The concentration detected at the surface depends on material permeability, ventilation, temperature, pressure and the available pathways.

    A higher hydrogen reading may therefore occur away from the original defect.

    This is why experienced interpretation is essential when investigating underground pipes or concealed heating circuits.

    3. Detection at Low Hydrogen Concentrations

    High-sensitivity sensors can measure very small concentrations of hydrogen gas.

    Hydrogen levels are commonly expressed in parts per million, with some specialist instruments capable of detecting concentrations around 0.1 ppm under specified conditions.

    However, 0.1 ppm describes a gas concentration, not the minimum size of a detectable water leak.

    A detector’s sensitivity does not automatically establish the location, diameter or water-loss rate of a pipe defect.

    Sensor technology, calibration, background hydrogen levels and environmental conditions all influence the measurements.

    The purpose of professional hydrogen detection is to identify meaningful changes in gas concentration and determine whether those readings provide evidence of leakage.

    Leak detected during hydrogen gas test on heating pipework.

    What Counts as a Very Small Leak?

    A very small plumbing leak is generally understood as a defect that releases a limited amount of water or produces symptoms that are difficult to identify.

    There is no single universal definition that applies to every domestic plumbing system.

    The significance of a leak depends on the pipe material, operating pressure, defect geometry and duration of water loss.

    A small pinhole in a pressurised copper pipe may release water continuously.

    A deteriorated joint may leak intermittently as temperature changes cause expansion and contraction.

    An underfloor heating circuit may lose pressure gradually without producing visible dampness above the floor.

    These examples demonstrate why leak size cannot be assessed from visible damage alone.

    A small defect can cause substantial water loss over time, while a larger defect may produce limited visible evidence if the escaping water drains into surrounding ground.

    Hydrogen tracer gas can help investigate these situations when the affected pipework can be isolated and tested appropriately.

    Our Hydrogen Leak Detection FAQs explain what homeowners can expect from a professional investigation.

    Hydrogen Detection Systems and Sensor Technology

    Hydrogen detection technology includes several different types of sensors and measurement systems.

    These technologies are not interchangeable, and equipment designed for industrial hydrogen safety monitoring is not necessarily suitable for locating concealed water leaks.

    The choice of detector depends on the intended application, required sensitivity and operating environment.

    High-Sensitivity Hydrogen Sensors

    High-sensitivity sensors are designed to detect small changes in hydrogen concentration.

    In plumbing tracer gas applications, portable instruments may be used to sample air around suspected pipe routes, floor joints and accessible penetrations.

    Some detectors incorporate an internal sampling pump that draws air towards the sensing element.

    The equipment converts the sensor response into a measurable reading, often displayed in ppm.

    Detector performance depends on calibration, response time, measurement range and environmental conditions.

    Electrochemical Sensors

    Electrochemical sensors detect gases through chemical reactions at an electrode.

    Depending on the sensor design, exposure to hydrogen produces an electrical signal associated with the measured gas concentration.

    These sensors are used in various hydrogen gas detection applications, including certain industrial safety systems.

    However, not every electrochemical sensor is appropriate for specialist plumbing tracer gas testing.

    The instrument must be selected for the intended measurement range and diagnostic procedure.

    Specialist hydrogen gas equipment set up for leak test in London

    Metal-Oxide Semiconductor Sensors

    Metal-oxide semiconductor sensors change electrical resistance when exposed to certain gases.

    They are used in various gas detection systems because they can be compact and responsive.

    However, sensor selectivity can be affected by other gases, temperature and humidity.

    Some semiconductor sensors may respond to hydrogen as well as other substances, depending on their design.

    This makes appropriate calibration and interpretation important when identifying leaks.

    Thermal Conductivity Sensors

    Thermal conductivity sensors measure differences in how gases transfer heat.

    Hydrogen has a relatively high thermal conductivity compared with many other gases, making this property useful in certain detection technologies.

    However, thermal conductivity sensors may have limitations when measuring very low hydrogen concentrations.

    Their suitability depends on the required detection range and the composition of the surrounding gas.

    Optical and Fibre-Optic Sensors

    Optical and fibre-optic sensors are used in specialist industrial applications.

    Some designs detect hydrogen through changes in optical properties when a hydrogen-sensitive material interacts with the gas.

    These technologies can support monitoring in complex industrial environments.

    However, they are not the standard equipment used for every domestic water leak investigation.

    Pellistor Sensors

    Pellistor sensors are commonly associated with combustible gas detection.

    They typically measure concentrations relative to the lower explosive limit (LEL) of a gas.

    Their primary application differs from that of a high-sensitivity tracer gas detector designed to identify very low hydrogen concentrations.

    A sensor suitable for industrial flammable gas alarms should not automatically be considered suitable for pinpointing a concealed plumbing leak.

    The important distinction is between detecting hydrogen as a potential industrial hazard and detecting hydrogen introduced deliberately as a tracer gas during a water leak investigation.

    Hydrogen tracer gas test confirms leak source under floorboards.

    How Hydrogen Tracer Gas Finds Micro-Leaks

    Hydrogen tracer gas testing uses a controlled investigation process to determine whether gas escapes from a suspected plumbing or heating circuit.

    The procedure must be adapted to the pipe material, operating pressure and accessibility of the installation.

    Step 1: Assess the Plumbing System

    The engineer examines the reported symptoms and identifies the pipework requiring investigation.

    This may include checking system pressure, accessible valves, visible connections and existing evidence of water loss.

    The purpose is to determine whether the suspected system can be isolated and whether hydrogen tracer gas testing is appropriate.

    Step 2: Isolate and Prepare the Pipework

    The relevant circuit is isolated where possible.

    The engineer assesses the condition of the system and establishes suitable test parameters.

    Correct preparation is important because connected pipework, open valves or unsuitable pressure conditions can affect the results.

    Step 3: Introduce the Tracer Gas

    A suitable hydrogen and nitrogen mixture is introduced under controlled pressure.

    The commonly used mixture contains approximately 95% nitrogen and 5% hydrogen.

    The selected pressure must remain within the appropriate limits for the pipework and its components.

    Hydrogen is used as a detectable tracer rather than as a fuel source.

    Step 4: Allow Hydrogen to Escape

    Where a pipe defect is present, tracer gas may escape through the opening.

    The amount of escaping hydrogen depends on the defect, pressure difference and surrounding conditions.

    A very small leak may release only a limited amount of gas.

    Consequently, additional time or repeated measurements may be required before a meaningful concentration change becomes apparent.

    Step 5: Measure Hydrogen Levels

    The engineer uses specialist detection equipment to sample accessible areas.

    These may include floor joints, pipe penetrations, wall cavities, suspected pipe routes and accessible fittings.

    The instrument measures hydrogen concentration, and readings are compared with background levels.

    Repeated measurements help determine whether the detected concentration is consistent with escaping tracer gas.

    Step 6: Interpret the Results

    Hydrogen readings are assessed alongside the plumbing layout, test pressure and surrounding construction.

    An increase in concentration may indicate that tracer gas is escaping from the suspected system.

    However, the highest concentration does not necessarily identify the precise defect location.

    Additional pressure testing, sectional isolation or another detection method may be needed before targeted access is recommended.

    Hydrogen leak detection test in progress inside North London property

    How We Investigate Very Small Hidden Water Leaks

    MML Plumbing provides specialist leak investigations for homeowners, landlords and commercial properties across London.

    Our engineers assess the reported symptoms and select appropriate diagnostic methods based on the plumbing system and available evidence.

    Where suitable, hydrogen tracer gas testing can help investigate very small leaks beneath floors, inside walls and within concealed heating circuits.

    We combine relevant findings with pressure testing, acoustic equipment, thermal imaging or other diagnostic techniques when necessary.

    Our objective is to identify the strongest available evidence of a concealed defect before recommending unnecessary opening works.

    1

    Book Your Leak Investigation

    Contact MML Plumbing to discuss unexplained pressure loss, suspected underground leaks or concealed water damage. Our team will explain the investigation process and arrange a suitable appointment with an experienced leak detection engineer.

    2

    Assess the Suspected Pipework

    Our engineer examines the plumbing system, accessible fittings, operating pressure and reported symptoms. We determine whether the affected pipework can be isolated and whether hydrogen tracer gas testing is appropriate.

    3

    Carry Out Specialist Leak Detection

    Where suitable, we introduce a controlled hydrogen and nitrogen tracer gas mixture into the prepared system. High-sensitivity detection equipment is used to investigate escaping gas and assess possible concealed pipe defects.

    4

    Prepare the Investigation Report

    We document relevant measurements, diagnostic methods and photographic evidence. Our insurance-ready Trace & Access report explains the findings and identifies recommended next steps based on the available evidence.

    5

    Recommend Appropriate Repairs

    Following the investigation, our engineer explains the results and discusses the most suitable repair approach. Where a concealed pipe defect is identified, we can provide recommendations or a quotation for targeted plumbing repairs.

    How we found hidden water leaks without damaging your home

    We Found 2 Hidden Leaks Under This Floor in North London!Play
    London’s Smartest Leak Detection Team? Watch What We Do…Play
    Hidden Water Leak Found Using Hydrogen Gas | Professional Leak Detection in N13 LondonPlay
    Boiler Losing Pressure in W10 London – Hidden Leak Found Using Hydrogen DetectionPlay

    Can Hydrogen Detection Identify Leaks Beneath Concrete Floors?

    Hydrogen tracer gas can be useful for investigating small leaks in pipework concealed beneath concrete floors.

    Concrete slabs, screed and floor finishes can make direct inspection difficult.

    A small leak may release water into the surrounding construction without creating an obvious damp patch.

    Hydrogen molecules may migrate through cracks, construction joints or other available pathways before reaching an accessible surface.

    Specialist sensors can then be used to investigate whether the escaping gas is detectable.

    However, concrete thickness, flooring materials, waterproof membranes and ventilation can influence gas movement.

    Some floor constructions may restrict hydrogen migration or cause the gas to emerge away from the actual defect.

    Therefore, a surface reading should not be interpreted as an exact pipe location without considering the surrounding construction.

    Hydrogen testing may help reduce unnecessary excavation, but it cannot guarantee that no opening work will be required.

    Can Hydrogen Detect Very Small Underfloor Heating Leaks?

    Underfloor heating systems can be particularly difficult to investigate because the pipework is frequently concealed beneath screed or finished flooring.

    A small defect may cause gradual pressure loss without producing visible water damage.

    The pipework may also be divided into multiple circuits connected to a manifold.

    When suitable, individual circuits can be assessed and isolated to help determine whether leakage is occurring.

    Hydrogen tracer gas may then be used to investigate the suspected circuit.

    The gas can escape through a defect and potentially migrate towards accessible surfaces.

    However, the effectiveness of testing depends on the pipe material, circuit arrangement, surrounding construction and test conditions.

    An inconclusive hydrogen test does not automatically establish that an underfloor heating circuit is leak-free.

    Where appropriate, the findings may be supported by pressure testing and thermal imaging.

    Thermal imaging leak detection carried out in Muswell Hill flat.
    Infrared heat map identifying hot water pipe leak – MML Leak Detection

    Why Traditional Detection Methods Can Miss Very Small Leaks

    Different leak detection technologies rely on different physical evidence.

    A method that works effectively for a significant leak may be less useful when investigating a very small defect.

    Pressure Testing

    Pressure testing assesses whether an isolated system maintains pressure under specified conditions.

    A pressure drop may indicate leakage, although temperature changes and other system characteristics must be considered.

    Pressure testing does not directly reveal the physical location of a defect.

    Hydrogen tracer gas may provide additional information when a pressure test suggests that leakage is present.

    Acoustic Detection

    Acoustic detection relies on the sound or vibration produced by escaping water.

    Very small leaks may generate insufficient noise for reliable identification.

    Plastic pipes, low operating pressure, background noise and surrounding construction can also influence acoustic readings.

    However, acoustic equipment remains effective for many suitable pressurised pipe systems.

    Hydrogen detection should be considered a complementary technique rather than a universal replacement.

    Thermal Imaging Cameras

    Thermal imaging cameras detect infrared radiation and display surface temperature patterns.

    They can help identify thermal anomalies associated with certain hot water or heating leaks.

    However, thermal imaging does not directly detect water or see through solid building materials.

    A very small leak may produce little measurable temperature difference.

    Insulation and surrounding heat sources can further complicate interpretation.

    Moisture Detection

    Moisture meters help identify changes in moisture conditions within accessible materials.

    However, elevated moisture readings do not establish the source of water.

    Moisture may result from plumbing leaks, condensation, external water ingress or other building defects.

    Water can also migrate considerable distances from the original pipe defect.

    Hydrogen tracer gas may therefore provide useful supporting evidence when a concealed plumbing leak is suspected.

    For more information about the different techniques used during professional investigations, visit our leak detection service in London.

    Can Hydrogen Detection Find Leaks Before Visible Damage Appears?

    Hydrogen tracer gas testing can sometimes identify a concealed pipe defect before visible water damage develops.

    For example, a central heating system may repeatedly lose pressure while the floors and walls remain dry.

    If the pressure loss is caused by a small concealed pipe defect, hydrogen tracer gas may help investigate the affected circuit.

    Similarly, an underground water supply may develop a small leak that increases water consumption without producing visible dampness inside the property.

    Early detection can help reduce further water loss and limit potential damage.

    However, hydrogen tracer gas testing is not normally a continuous monitoring system for domestic plumbing.

    It is a diagnostic procedure undertaken when leakage is suspected.

    The method cannot guarantee that every defect will be identified before damage occurs.

    Tiny Leaks Versus Larger Leaks: How Detection Sensitivity Works

    Hydrogen concentration readings are influenced by several factors beyond the size of the defect.

    A small leak may produce a relatively low concentration because only a limited amount of gas escapes.

    However, a larger leak may also produce a low reading if the gas disperses rapidly or cannot reach the sampling location.

    Conversely, hydrogen may accumulate around a particular joint or enclosed area, creating a higher concentration.

    This means the relationship between leak size and measured hydrogen concentration is not always straightforward.

    A reading of 1 ppm does not correspond to one particular water leak rate.

    Similarly, a reading of 20 ppm does not automatically establish that a leak is twenty times larger.

    Professional leak detection requires the engineer to assess concentration changes, sampling locations, test pressure and gas migration.

    The sensitivity of the detection equipment is important, but reliable interpretation is equally necessary.

    For details of our specialist service, see hydrogen tracer gas leak detection in London.

    Acoustic water leak detection for homes & businesses – Call today!
    Endoscope leak detection in Hampstead – MML Plumbing van on site for investigation.

    What Can Affect Hydrogen Detection Accuracy?

    Several environmental and technical factors can influence the accuracy of hydrogen tracer gas testing.

    Pipe pressure: The pressure difference across a defect influences the amount of tracer gas that may escape.

    Pipe material: Copper, plastic and other materials can behave differently under pressure and temperature changes.

    Concrete and flooring: Dense materials, membranes and construction layers may restrict gas migration.

    Ventilation: Air movement can dilute hydrogen concentrations or move gas away from the suspected defect.

    Background hydrogen: Existing atmospheric hydrogen levels and other environmental conditions can affect measurements.

    Sensor technology: Different sensors have different detection limits, response times and selectivity.

    Temperature and humidity: Environmental conditions can influence both gas movement and detector performance.

    System isolation: Connected pipework or unsuitable valve arrangements may affect the reliability of the test.

    These factors explain why a hydrogen detector should not be treated as an instrument that automatically identifies the exact position of every leak.

    A reliable investigation depends on suitable equipment, controlled procedures and experienced interpretation.

    Is Hydrogen Tracer Gas Safe for Detecting Small Water Leaks?

    Hydrogen is a flammable gas when mixed with air within certain concentration ranges.

    Pure hydrogen has a lower flammable limit of approximately 4% by volume in air.

    Hydrogen also has a relatively low ignition energy, meaning that an appropriate flammable mixture can ignite when exposed to a sufficient ignition source.

    These properties are important in industrial hydrogen systems, hydrogen fuel applications and facilities that store or produce hydrogen.

    However, professional plumbing tracer gas testing uses a different approach.

    A commonly used forming gas mixture contains approximately 95% nitrogen and 5% hydrogen.

    The mixture is selected for controlled leak testing applications and must be used in accordance with its specification and the relevant safety procedures.

    The engineer must assess the test environment, pipework, equipment and pressure limits before introducing tracer gas.

    Although hydrogen disperses readily in many environments, enclosed spaces and ventilation conditions must still be considered.

    Professional tracer gas testing should never be described as completely risk-free.

    For further information, read ” Is hydrogen leak detection safe in homes?.

    Engineer performing hydrogen tracer gas pipe leak test

    Hydrogen Gas Detection Versus Hydrogen Tracer Gas Leak Detection

    The term hydrogen leak detection can refer to two different applications.

    The first involves detecting hydrogen gas escaping from systems that use, transport, store or produce hydrogen.

    These applications may include industrial hydrogen production, fuel cells, water electrolysis equipment, hydrogen storage facilities and other technologies associated with the hydrogen economy.

    In these environments, hydrogen gas leaks can create safety hazards.

    Detection systems may monitor hydrogen levels continuously and activate alarms or shutdown procedures when concentrations exceed specified thresholds.

    Such systems are designed to mitigate risks associated with flammable gas, ignition sources and potentially explosive mixtures.

    The second application involves deliberately introducing a controlled hydrogen tracer gas mixture into suitable plumbing or heating pipework.

    In this case, hydrogen is used to investigate an existing or suspected water leak.

    The purpose is not to monitor hydrogen fuel systems or prevent hydrogen-related industrial accidents.

    Instead, the engineer uses sensitive detection equipment to investigate whether tracer gas escapes through a concealed pipe defect.

    This article concerns the second application: using hydrogen tracer gas to identify very small water leaks.

    Understanding this distinction is important because the equipment, detection thresholds, safety requirements and interpretation methods differ between the two applications.

    Why Hydrogen Is Used Instead of Other Tracer Gases

    Several gases can be used for specialist leak testing.

    Hydrogen is useful because of its small molecular size, low density and compatibility with suitable high-sensitivity detection equipment.

    Helium is another gas used in industrial leak testing and other specialist applications.

    Nitrogen and compressed air can also be used for certain pressure-testing procedures, although the methods and detection capabilities differ.

    The choice of gas depends on the required sensitivity, equipment, system compatibility and test conditions.

    Hydrogen should not automatically be considered the best gas for every application.

    For concealed domestic plumbing investigations, the practical objective is to use an appropriate method that provides reliable evidence of leakage.

    Our guide to why hydrogen is used instead of other gases for leak detection explains these differences in more detail.

    When Is Hydrogen Detection Suitable for Very Small Leaks?

    Hydrogen tracer gas may be suitable when a small concealed water leak is suspected but cannot be identified through accessible inspection.

    Common situations include repeated central heating pressure loss, suspected underfloor heating leaks, concealed copper pipe defects and underground water supply leaks.

    It may also be useful when previous acoustic or thermal investigations have produced inconclusive findings.

    However, hydrogen testing is not necessary for every plumbing problem.

    An accessible dripping connection, leaking valve or visible pipe defect may be identified and repaired without specialist tracer gas equipment.

    Similarly, a system that cannot be isolated or prepared safely may require a different diagnostic approach.

    The correct method depends on the reported symptoms, system design and evidence available during the investigation.

    Environmental and Energy Efficiency Benefits of Finding Small Leaks

    Very small water leaks can create significant waste when they remain active over long periods.

    A concealed cold-water pipe defect may release water continuously, increasing consumption and potentially affecting the surrounding ground or building materials.

    In heating systems, repeated pressure loss may lead to frequent topping up and unnecessary disruption.

    Finding leaks early can reduce water waste and help prevent further damage.

    Accurate diagnosis may also reduce unnecessary removal of tiles, flooring and other building materials.

    This can lower the amount of waste generated during investigation and repair.

    Although hydrogen detection technology also plays a role in industrial energy efficiency and hydrogen fuel systems, its principal environmental benefit in domestic plumbing is helping identify water loss and support targeted repairs.

    What Happens When a Very Small Leak Is Identified?

    When testing provides evidence of a concealed pipe defect, the engineer evaluates the findings and recommends the appropriate next steps.

    The report should explain which system was investigated, the diagnostic methods used and the relevant measurements.

    Where hydrogen readings support a suspected leak location, the findings can help plan targeted access.

    However, the investigation must distinguish between a confirmed defect and an area where leakage is suspected.

    Additional testing may be necessary when gas migration or construction conditions make the results uncertain.

    At MML Plumbing, our investigations can include photographic evidence, pressure measurements and relevant diagnostic findings.

    We provide insurance-ready Trace & Access reports that explain the investigation and recommended next steps.

    Where appropriate, we can also provide a quotation for the necessary plumbing repairs.

    How Can You Tell Whether a Water Leak Is Inside the House or on the External Supply Pipe?

    Water meter monitoring and controlled isolation testing can help determine whether water is escaping from internal plumbing or the underground supply pipe. During our external mains water leak detection case study in North London N11, our engineers isolated the internal water system, but the external meter continued registering water flow. Additional hydrogen tracer gas testing found no evidence of leakage within the tested internal pipework. These findings directed the investigation towards the underground incoming supply, avoiding unnecessary opening of internal floors and walls. We recommended installing a replacement cold-water main and documented the findings to support the homeowner’s repair planning.

    Floor heating pipe leak inspection by experienced engineer
    MML Plumbing van driving near Buckingham Palace, London.

    Professional Conclusion: Can Hydrogen Detection Find Very Small Leaks?

    Hydrogen tracer gas detection can identify very small concealed water leaks, including defects that produce insufficient sound, moisture or temperature change for other detection methods.

    Its effectiveness comes from the physical properties of hydrogen molecules and the sensitivity of specialist gas detection equipment.

    However, the smallest detectable leak depends on the system pressure, defect characteristics, detector performance and surrounding environment.

    Hydrogen concentration measurements must not be confused with water leak rates or guaranteed location accuracy.

    The most reliable results come from controlled testing, repeated measurements and interpretation alongside the plumbing system’s condition.

    For concealed heating pipes, underground water supplies and underfloor heating circuits, hydrogen tracer gas can provide valuable diagnostic evidence while helping minimise unnecessary disruption.

    This guidance reflects the types of concealed plumbing and heating investigations undertaken by MML Plumbing across London. You can also find our verified business information on our Google listing.

    We Find the Leak Before It Finds You – Book Expert Detection Today

    Frequently Asked Questions

    Question not answered? Ask A Question

    Can hydrogen detection find a pinhole leak in a copper pipe?

    Hydrogen tracer gas may help identify a small pinhole in a copper pipe if the affected system can be isolated and tested appropriately. Detection depends on the size of the defect, test pressure, surrounding construction and whether escaping gas reaches an accessible sampling point.

    Can hydrogen detection identify a leak that only occurs when the heating is on?

    It may help investigate an intermittent heating pipe defect, but the results depend on whether the defect remains open under the test conditions. Some leaks change with temperature and pressure, so additional investigation may be required.

    Does a higher hydrogen reading mean the water leak is larger?

    Not necessarily. Hydrogen concentration is influenced by gas migration, ventilation, test pressure and the distance between the defect and sampling point. A higher ppm reading does not directly establish the water leak rate.

    Request a booking

    Or call us and we'll book you in now:

    02083550840

      Can't call us? You can still request a booking by filling out the form below:

      After you complete the contact form, our team will quickly get back to you with booking times, prices, and terms & conditions.