Why frequent refilling is the symptom, not the cure
A sealed heating system should hold its charge for months, so when someone tells us they are topping up weekly, we already know something is draining it steadily. We have watched it happen on the doorstep — the homeowner tops up through the filling loop, the gauge climbs to its normal reading, the heating behaves for a few hours or a day, then the needle starts sliding again. What we are really looking at is the same loss repeating on a loop. The refill was never a repair; it just masks how much water the system is shedding between visits, and the tighter the interval, the greater the likelihood the leak is active rather than trivial. The first thing we ask is how many days between top-ups, because that interval tells us more than the gauge ever will.

The quick faults we rule out at the boiler.
Before anyone lifts a floorboard, we clear the boiler-side faults that behave like a leak, because chasing buried pipework on a system bleeding internally helps no one. A safety valve that no longer seats properly will pass system water out through the overflow pipe to the exterior — and time and again the only tell-tale we find is a dripping or perpetually damp patch on an outside wall, often the first place we walk round to check. A faulty expansion vessel gives itself away differently, through the swing of the needle: we watch the pressure rise high as the system heats, then drop low as it cools, because the vessel can no longer absorb the change in temperature. Where it has simply lost its charge, a heating engineer can sometimes recharge it rather than replacing it outright. Recently bled rads will also let the pressure settle downward while the last of the trapped air clears, which sorts itself out. These take us minutes to check off. When they are clear, and the loss carries on, the water is leaving the system somewhere we cannot see.
Why you will rarely spot the leak yourself
We have traced leaks losing barely a cupful a day that still dragged the gauge down every week — which is exactly why these faults defeat the naked eye. There is so little spare water in a sealed circuit that a pinhole most people would never notice is enough to keep the pressure falling. More often than not it never surfaces as a wet patch, because we find it wicking into a subfloor cavity or running along a warm pipe and evaporating before it reaches anywhere you could see. The trouble hides where you cannot inspect it: unions under suspended timber, copper runs cast into screed or concrete, elbows behind plasterboard, and underfloor heating loops. Plenty of homeowners meet us at the door certain there is no leak because nothing looks wet — but on a concealed heating fault, nothing looking wet is precisely what we expect to find.

How we locate a leak that stays out of sight
With the leak buried, a guess means opening the wrong floor, and we have been brought in to put right too many of those to work that way. So we stay non-invasive, stacking one method on the next until every reading points at the same spot. We open with pressure testing, isolating the heating circuit to prove water is genuinely being lost and to narrow the search to one part of the system. Then we bring in thermal imaging, reading the heat signature of the pipework against its cooler surroundings — on the right floor it lights up the concealed run and shows us water pooling beneath a surface we never have to touch. Acoustic detection goes on alongside it, and there are jobs where the faint hiss of water forcing out of a pressurised pipe is the thing that gives the fault away, while moisture mapping shows us where water has already gathered in the fabric. When a leak is fine enough that its exact position still eludes us, hydrogen tracer gas settles it — we introduce a harmless hydrogen-nitrogen blend into the drained system and follow it up through the structure to the one point it escapes. Where there is a route in, borescope and CCTV let us set eyes on the fault before a tile is disturbed. No single tool closes the case; it is watching them agree with one another that lets us mark the floor and be certain.
Is a system that needs constant topping up dangerous?
The low pressure itself poses little immediate danger, since most modern systems simply lock out rather than run in a fault state. The hazard is whatever is draining the water. We have lifted floors weeks into a slow leak and found the joists already sodden, the screed saturated and the first signs of rot setting into the timber — all from a loss so quiet the homeowner had done nothing but keep refilling. Catching it early is how we protect the building fabric, and it is the reason we would always rather trace the source now than watch someone settle into a habit of topping up.


Case study — real-life experience in Finchley
We were called to a house in Finchley where the owner had been quietly refilling the boiler every couple of days, convinced there was no leak because every room was bone dry. Pressure testing settled the first question fast — the system was genuinely shedding water. From there we brought in thermal imaging, moisture mapping and acoustic detection, and the readings converged on a single spot: a slow weep at a heating joint buried under the hallway screed, evaporating into the subfloor long before it could surface. Because we had it pinned to the exact point, the repair meant opening one small section of floor rather than lifting the length of the hall, and the guesswork was over before it started. This is one example of many where proving the location first saved a homeowner from unnecessary damage.
Why homeowners across London call us
Insurers handling a trace-and-access claim want the cause pinned down and documented, and that is what our reports give them. We are a specialist leak detection company covering London and North London, and in more than 15 years our team has built its reputation on finding what other trades walk away from. Fully insured and 5-star rated, we hand over a clear, insurance-ready report on every job. Much of our diary is filled by people who have already paid once for guesswork that missed — so we settle the question with evidence before anyone reaches for a cutting tool.
Related questions
Repeated boiler pressure loss can sometimes be linked to faults that behave differently as the system heats, cools or is repressurised. These related questions explore other possible causes and pressure patterns that can help narrow down what is happening.
- Could two separate concealed leaks be causing pressure loss from the same heating system?
- Why does my boiler lose pressure again soon after I have repressurised it?
- Can trapped air cause pressure fluctuations that look like water is escaping?
- Can a concealed heating pipe beneath concrete leak without producing obvious damp?
- Why can boiler pressure continue falling after the radiators have been bled and the system repressurised?

Book a non-invasive leak detection survey.
Refilling the boiler on a three-day cycle is not maintenance; it is feeding a leak — so before the next top-up, contact MML Plumbing and let us find out where the water is actually going. Using non-invasive leak detection, we will tell you whether the fault lies at the boiler or on a concealed heating run, and pinpoint it precisely. The longer a slow leak runs, the further the damage spreads: what begins as a dropping gauge ends as soft joists and stained ceilings, and that bill lands in flooring and plaster, not in a bit of topping-up. Our method never changes because it is the one that works — rule out the boiler-side faults, prove the loss with pressure testing, then read the system with thermal imaging, acoustic detection, moisture mapping and hydrogen tracer gas until the source is beyond doubt. You are left with an exact location, a straightforward explanation, and an insurance-ready report to act on.
Real Leak Detection Examples From North London Homes
Real Investigations from the Field
This section features real boiler pressure loss and hidden heating leak investigations carried out by MML Plumbing across London. Each case shows the symptoms reported, the testing methods used, the evidence found and the confirmed cause of the problem.
These real-world investigations demonstrate how pressure loss and concealed heating leaks are investigated in practice, using evidence to narrow down the source before unnecessary repairs or destructive access are considered.

Boiler Losing Pressure – Two Hidden Heating Leaks Found
A North London homeowner’s boiler was losing pressure rapidly, dropping by around 1 bar in under 10 minutes; our leak detection investigation identified two concealed pipe leaks beneath tiled and concrete floors, which were located, repaired and pressure-tested until the system remained stable. Read the full case study →

Boiler Losing Pressure – Multiple Hidden Faults Found in SW19
A large heating system in SW19 was losing around 3 litres of water per day with no obvious leak; our investigation identified multiple sources of pressure loss, including radiator and air-vent leaks, plus evidence of an internal heating-to-hot-water crossover. MML Plumbing: Read the full case study →

Hidden Heating Leak Traced Beneath the Floor in NW3
A heating system in Hollycroft Avenue, NW3, was repeatedly losing pressure with no visible leak; thermal imaging and hydrogen tracer gas testing produced readings of approximately 1,000 ppm, narrowing the suspected leak to concealed pipework near the plant room and bathroom.