No guessing. No damage. Just clear answers.
What affects how long it takes?
These are the variables that decide whether a job takes two hours or most of a day when a boiler losing pressure needs investigating, with the timing driven mainly by access, system complexity, and how severe the pressure loss is:
- Floor construction. Suspended timber with a reachable void is quicker than solid concrete or screed.
- How fast the system is losing pressure. The speed and severity of the pressure drop both affect how long diagnosis takes, because a lively leak gives the instruments more to pick up than a slow weep.
- Property size. The size of the property affects investigation time, because longer heating runs mean more pipe to isolate and test.
- Heating system type. Different layouts and system types can make leak diagnostics quicker or slower.
- How far the water has travelled. Water can run along a joist or through screed well away from the leak.
- Which methods the leak needs. Some are confirmed with thermal imaging alone. Others need tracer gas.
- More than one fault. Occasionally there’s a second leak, or a leak plus a faulty component at the boiler.
- Access on the day. Accessibility of pipework can add time, especially where pipes are concealed, and furniture over the suspect area, locked rooms or a boarded-over loft hatch all slow things down.

What happens during the visit, step by step?
Most visits follow the same order. Knowing it helps you plan your day.
1. Initial checks (roughly the first half hour). We talk through what you’ve noticed and look at the boiler pressure gauge, the filling loop, the safety valve and its outlet pipe on the outside wall, and the visible pipework. This rules out obvious non-leak causes like a passing relief valve or a filling loop left open.
2. Confirming the loss. We pressure test the heating system to prove water is actually leaving and measure how fast. That tells us the size of the leak we’re looking for.
3. Isolating the circuit. We split the heating pipework into sections and test each one on its own. This is the step that saves the most time. It usually rules out most of the property, so we’re searching one run, not the whole house.
4. Tracing the run. Thermal imaging follows the losing run through the floor or wall. With the system hot, a leak often shows as a cooler bloom spreading off a warm pipeline. Moisture mapping and acoustic detection then confirm the area.
5. Pinpointing, if needed. If the leak still won’t show itself, we use hydrogen tracer gas. This means draining the water from that section and filling it with a safe gas mixture, which rises out at the exact point of failure. It’s the most precise method, and it adds time.
6. Marking and reporting. We mark the spot, explain what we’ve found and follow up with a written, insurance-ready report.
What gets ruled out first, and can that shorten the visit?
Before we look for a hidden leak, we check the common reasons boiler pressure falls that have nothing to do with the pipework. These checks are quick, and occasionally they end the visit early because the cause isn’t a leak at all.
- A faulty pressure relief valve. If the pressure relief valve doesn’t reseal, water escapes through the outlet pipe outside, and a leaking pressure relief valve can cause continuous pressure loss. A wet pipe or a drip on the wall below points to this. If it is faulty, it needs a qualified engineer to assess or replace it.
- Expansion vessel problems. When water heats, water expands, and the expansion vessel takes up the extra volume. A faulty expansion vessel that has lost its air charge can cause significant pressure fluctuations and let too much pressure build when hot. High pressure opens the relief valve, and the system pressure then falls once it’s cold.
- Trapped air. If you’ve been bleeding radiators, the pressure can temporarily drop as the air leaves. That’s normal, and one top-up should hold, but air trapped in the system can also contribute to pressure loss.
- The filling loop. A loop left slightly open lets cold water creep in and can hide a leak or cause swings in water pressure.
- Internal components. A weeping heat exchanger or a leak inside the boiler casing leaves marks underneath. Those are boiler repairs, covered by the boiler manufacturer’s guidance, not something a pipework survey fixes.
Small pressure changes between hot and cold are normal in a sealed system. If pressure drops keep happening, you need a professional inspection, and any work on a gas appliance must legally be done by a Gas Safe registered engineer. If none of the above explains your boiler pressure dropping, we move on to the pipework, where most pipework leaks we find are hidden.

Why do some jobs take longer?
Mostly access, plus a few other variables.
Solid floors take more reading. Concrete and screed hold heat and moisture differently from timber, so the thermal and moisture patterns spread wider and take more care to read. On suspended floors, we can often confirm from the void below.
Slow weeps give less to detect. A tiny leak still empties a sealed central heating system within days, because the system holds so little spare water. But it gives off very little heat, moisture or sound. The smallest leaks can take the longest to pin down, and they’re usually where we layer more methods together.
Large properties have more pipe. A four-bedroom house with long runs, or a system feeding a hot water cylinder, towel rails and an extension, simply has more to isolate.
Underfloor heating and crossing pipes complicate the picture. Thermal images can mislead where pipes cross, or underfloor heating is present, so we cross-check more before marking anything.
Tracer gas adds a drain-down. If the job needs it, the affected section has to be drained and later refilled and re-pressurised.
None of these turns it into a marathon. They’re simply why one job takes two hours, and another takes most of the day.
Why do we take the time to be thorough?
Because the whole value of the visit is getting the location right.
If a floor is opened a foot away from the actual leak, that’s damage done for nothing and another opening needed. That’s exactly the outcome the investigation is meant to prevent. So we don’t mark anything until the methods agree: pressure testing, thermal imaging, moisture mapping, acoustic detection and, where needed, tracer gas all pointing to the same place.
That cross-check might add half an hour. From what we’ve seen, it’s the most valuable half hour of the visit.
MML Plumbing is a specialist leak detection company. Our job is the diagnosis. The repair is carried out afterwards at the spot we’ve proven, so it’s quick and targeted too.
How can you help the visit go faster?
A little preparation can save real time on the day. Before we arrive:
- Keep a pressure record. Check the boiler pressure gauge regularly, ideally monthly, and note it each morning with the system cold for a few days before the visit. It tells us the rate of loss before we start.
- Top up to the correct pressure the day before using the filling loop to refill the heating system. Open the filling loop valves slowly to avoid pressure spikes, and bring it to the normal cold range of 1.2 to 1.5 bar, with the needle in the green zone if marked there; once it reaches 1.5 bar, close the valves again. Pressure can rise to about 2 bar when hot. After repressurising, check for leaks.
- Don’t bleed radiators on the morning of the visit. If you’ve recently bled radiators, tell us, because it affects the readings.
- Clear access to the boiler, the filling loop, the hot water cylinder if you have one, and all the radiators.
- Move rugs and furniture from any room where you’ve noticed a cold spot, a warm patch on the floor or damp patches.
- Have the radiator key handy and know where your loft hatch and any manifolds or access panels are.
- Tell us about recent work. A new radiator valve, circulation pump or boiler can point us straight to the right area.


Will the heating be off during the investigation?
For parts of it, yes. We need the heating on at times, because thermal imaging works best when water heats the pipes and shows up the runs. At other times, sections are isolated or drained for testing, so the heating and hot water may be off for a while.
On a combi boiler, hot water is usually only interrupted for the stages where the system is isolated or drained. We’ll tell you before anything is switched off.
Is low boiler pressure dangerous while you wait for a visit?
Not usually to you. Most modern boilers, whether a gas boiler or another type, have a safety measure that locks the boiler out when the pressure drops too low, and pressure below 0.9 bar may cause boiler shutdown. That’s normal operation for a pressurised system with a leak, not a fault in itself, though persistent pressure loss can keep triggering shutdowns. For safety, boilers should not exceed 3 bar.
If pressure drops below 0.9 bar, call a boiler engineer.
The risk is to the building. Every top-up feeds the leak, and the water goes into floors and walls. Low pressure also isn’t something an annual boiler service will fix if the cause is a leak in the pipework, and a heating engineer may be needed if the system needs testing or repair. If the boiler pressure keeps dropping quickly, or you see water coming through a ceiling, turn the heating off and get in touch straight away.
What if the leak isn’t found in one visit?
It’s uncommon, but it happens, usually with a very slow weep that barely registers on the day. If a system only loses a fraction of a bar over several days, a short test can show the loss without giving the instruments enough to locate it precisely. When it does, we explain what we’ve ruled out and what we’ve narrowed it to, and agree the next step with you, such as a further test once the loss has had time to show more clearly. You won’t be left without an answer about what we found and what comes next.
Related questions

Real Leak Detection Examples From North London Homes
Real Investigations from the Field
This section features real boiler pressure loss and hidden heating leak investigations carried out by MML Plumbing across London. Each case shows the symptoms reported, the testing methods used, the evidence found and the confirmed cause of the problem.
These real-world investigations demonstrate how pressure loss and concealed heating leaks are investigated in practice, using evidence to narrow down the source before unnecessary repairs or destructive access are considered.

Boiler Losing Pressure – Two Hidden Heating Leaks Found
A North London homeowner’s boiler was losing pressure rapidly, dropping by around 1 bar in under 10 minutes; our leak detection investigation identified two concealed pipe leaks beneath tiled and concrete floors, which were located, repaired and pressure-tested until the system remained stable. Read the full case study →

Boiler Losing Pressure – Multiple Hidden Faults Found in SW19
A large heating system in SW19 was losing around 3 litres of water per day with no obvious leak; our investigation identified multiple sources of pressure loss, including radiator and air-vent leaks, plus evidence of an internal heating-to-hot-water crossover. MML Plumbing: Read the full case study →

Hidden Heating Leak Traced Beneath the Floor in NW3
A heating system in Hollycroft Avenue, NW3, was repeatedly losing pressure with no visible leak; thermal imaging and hydrogen tracer gas testing produced readings of approximately 1,000 ppm, narrowing the suspected leak to concealed pipework near the plant room and bathroom.
Book a single-visit investigation at a time that suits you
If your boiler keeps losing pressure, you don’t need to lose days to find out why. Most investigations are one visit, and in most cases you’ll know where the water is going by the end of it.
MML Plumbing will find the leak, prove it and show you exactly where it is, with as little disruption as the leak allows.
- Usually a single visit, often a morning or an afternoon
- One small opening, because we prove the spot before anything is lifted
- A written, insurance-ready report for any trace and access claim
- Fully insured and 5-star rated, working across London and North London
Booking is simple:
- Call or send the form. Tell us about your property, your floors and how often you’re topping up.
- We give you a realistic time estimate and book a slot that suits your day.
- We find it, mark it and put it in writing.