No guessing. No damage. Just clear answers.
What are the signs the boiler losing pressure is due to trapped air, not a leak?
- The pressure fell straight after bleeding radiators
- radiators or towel rails with cold spots at the top, or you can hear water flowing and gurgling when the heating runs
- a one-off pressure drop that holds steady after a single top-up
- the reading settling and staying put over the following days
- no damp patches, no water dripping anywhere, and no discharge from the small copper pipe outside
- The system was recently drained, refilled or had work done on it

How does trapped air make the boiler pressure drop?
A sealed heating system is meant to hold water and nothing else. Air gets in through a few ordinary routes:
- Fresh water. Every time you re-pressurise, cold water from the mains brings dissolved air with it, which comes out of solution as the water heats.
- Drain-downs. Air is introduced whenever the system is drained and refilled for work.
- Corrosion. Chemical reactions inside radiators produce gas over time.
That air collects at the high points and in the tops of radiators, which is why they go cold at the top and need bleeding.
Here’s the part that catches people out. Air takes up space in the system. When you bleed a radiator, the air leaves, water moves in to fill the gap, and the pressure falls. So a gauge that drops straight after bleeding isn’t showing a leak. It’s the system rebalancing, and one top-up puts it right.
What pressure should my boiler be at?
Normal boiler pressure for most modern combi boilers, and most boilers generally, is about 1.0 to 1.5 bar when the system is cold. It will rise slightly as the water heats and expands, and settle back as the system cools. The exact pressure for your boiler model is in the boiler manual. A drop into the red after bleeding is expected. A pressure level that keeps falling after you’ve topped it up is not normal. Low boiler pressure that keeps returning means system pressure is being lost because water is escaping somewhere, and modern boilers will usually lock out when the water pressure gets too low, with some newer models also showing an error code.

How do I re-pressurise after bleeding the radiators?
Most sealed systems are topped up through the filling loop, a braided hose with two valves under the boiler:
- Let the heating system cool, so you’re reading the true cold pressure.
- Open both valves slowly and watch the boiler pressure gauge.
- Close the valves tightly once the needle reaches about 1.5 bar, or the figure in your boiler manual.
- Check both are fully shut. A loop left slightly open lets water keep passing into the system.
If you overshoot, the pressure relief valve is there as a safety measure. It will release water through the small pipe outside if the pressure climbs too high.
How do I know it’s air and not a leak?
Timing and repetition tell you almost everything.
Air causes a drop once. You bleed the radiators, the pressure falls, you top it back up into the green zone, and that’s the end of it. The reading holds from then on.
A leak keeps coming back. When the boiler losing pressure becomes a repeating pattern, you top it up; it looks fine for a day or two, then the pressure falls again, and you’re back at the filling loop within the week.
The test costs nothing:
- Bleed any radiators that need it.
- Top the pressure up once to the correct pressure.
- Watch the gauge at the same time each day for five to seven days.
Small pressure changes between hot and cold are normal. If it stays put, it was air and the matter is closed. If it creeps back down, air was never the real problem. The system is losing water, and that’s a different job entirely.
Could it be something other than air, a leak, or a faulty pressure relief valve?
A few other faults can make the pressure fall without an obvious leak:
- A failing expansion vessel. If it has lost its charge, pressure spikes when the heating runs, the pressure relief valve releases water, and the pressure falls as the system cools.
- A faulty pressure relief valve. A valve that doesn’t reseal lets water out through the discharge pipe. Check for a drip or a wet mark below the pipe outside.
- A faulty pressure gauge. Rare, but a gauge that sticks can give false readings.
- Internal components. A weeping heat exchanger or a leak inside the hot water cylinder coil can lose water with no visible leaks, so it helps to understand the specific boiler setup involved, whether that is a combi boiler or another system type.
These are repairs to the boiler and its internal components, which isn’t work MML Plumbing takes on. What we do is prove whether the system is actually losing water and, if so, where it’s going. Any diagnosis of boiler or internal-component faults should be handled by a qualified engineer.


Can I have trapped air and a leak at the same time?
Yes, and this is why people go round in circles.
A small hidden leak loses water. Every top-up then adds fresh cold water full of dissolved air, which collects in the radiators. So you get cold spots and a falling gauge together. Bleeding clears the cold spots and drops the pressure. You top up, and for a few days everything seems better. Then it slides again, because the leak never went anywhere.
We see this a lot. Someone has been bleeding and topping up for weeks, convinced it’s just persistent air, when the air was only ever a symptom of the system leak. If you keep having to bleed the radiators, that’s the tell. Air that keeps coming back usually means water is getting out.
When should I stop bleeding and get it looked at?
When the same problem keeps coming back after you’ve dealt with it properly.
Bleeding radiators once or twice a year, alongside an annual service and regular maintenance, is normal. It keeps a heating system running smoothly. Bleeding every couple of weeks, or topping up on any regular basis, is not normal. That’s a system telling you it’s losing water and gaining air to replace it. At that point, more bleeding and topping up only manage the symptom. If the pressure problem keeps returning, have it checked by a Gas Safe engineer.
This is where MML Plumbing comes in. We’re a specialist leak detection company. Our job is to establish whether you have a genuine leak and find exactly where it is.

What if it turns out to be a real leak?
Then the boiler pressure loss is water escaping somewhere in the pipework, and that’s where our work begins.
A sealed system holds so little spare water that even a leak far too small to see will pull the gauge down within days. We’ve traced leaks losing so little that a week’s worth would fit in a mug. They give almost nothing away: no obvious signs, no visible signs of staining, no damp patches. The water either soaks into a subfloor void or dries against a warm pipe before it reaches a surface.
If the system is older and keeps leaking or failing, it may be time to consider a new boiler. A properly maintained boiler can often last 10 to 15 years.
These water leaks hide in the concealed runs: beneath suspended floors, cast into screed, or dropping inside walls to feed the radiators and radiator valves. Air that keeps needing to be bled is often the first clue that one of those runs is quietly losing water.
How does MML Plumbing find the leak?
We narrow the search before we open anything, because guessing which floor to lift is what we’re usually called in to correct.
First, we pressure test the system to prove the loss is genuine and separate a real leak from a system that simply had air trapped in it. Then we isolate sections of the heating circuit and test each one on its own, so we can say which run is losing and which is holding. That step alone usually rules out most of the property.
From there we read the structure with instruments rather than assumptions:
- Thermal imaging traces pipe runs through floors and walls. We look for a soft, cooler bloom spreading off a clean warm line, not a dramatic hot spot.
- Moisture mapping shows where water leakage has gathered in the building fabric, even where the surface feels dry.
- Acoustic leak detection listens for the thin hiss of water escaping under pressure.
- Hydrogen tracer gas pinpoints the exact position when a leak still won’t show itself, rising out at the single point where the pipe has failed.
No single method closes the case alone. A thermal image can mislead where runs cross or underfloor heating is present, so we only mark the floor once the methods agree.
Low pressure caused by a hidden leak never fixes itself. Finding it does.

What equipment does an MML Plumbing survey use?
- thermal imaging camera
- moisture meter and moisture mapping
- acoustic leak detection
- pressure testing equipment
- hydrogen tracer gas
- borescope and CCTV
- torch and inspection mirror
When the camera, the moisture readings and the tracer gas agree on one spot, that’s where we open up, and the opening stays small.
Why does it pay to know which one you’re dealing with?
Trapped air and a hidden leak look identical on the gauge, but they need completely different things. One is a five-minute top-up. The other is water escaping into your home.
In more than 15 years working across London and North London, MML Plumbing has been called to plenty of systems written off as “just air” that were quietly leaking. We’ve also found genuine air problems that needed nothing more than a proper bleed and a top-up. Where a boiler fault is suspected, it should be checked by a gas engineer or a Gas Safe registered engineer as appropriate. We’re fully insured and 5-star rated, and every survey ends with a written, insurance-ready report setting out what was tested, what was found and where any water is going. That’s the document your insurer will want if a trace and access claim follows.
Related questions
- Why am I having to refill my boiler pressure every few days?
- Should a sealed heating system gradually lose pressure over time?
- Can frequent repressurising cause problems inside my heating system?
- Can water escaping from a radiator reduce central heating system pressure?
- Could a filling-loop fault be connected to recurring pressure problems?

Real Leak Detection Examples From North London Homes
Real Investigations from the Field
This section features real boiler pressure loss and hidden heating leak investigations carried out by MML Plumbing across London. Each case shows the symptoms reported, the testing methods used, the evidence found and the confirmed cause of the problem.
These real-world investigations demonstrate how pressure loss and concealed heating leaks are investigated in practice, using evidence to narrow down the source before unnecessary repairs or destructive access are considered.

Boiler Losing Pressure – Two Hidden Heating Leaks Found
A North London homeowner’s boiler was losing pressure rapidly, dropping by around 1 bar in under 10 minutes; our leak detection investigation identified two concealed pipe leaks beneath tiled and concrete floors, which were located, repaired and pressure-tested until the system remained stable. Read the full case study →

Boiler Losing Pressure – Multiple Hidden Faults Found in SW19
A large heating system in SW19 was losing around 3 litres of water per day with no obvious leak; our investigation identified multiple sources of pressure loss, including radiator and air-vent leaks, plus evidence of an internal heating-to-hot-water crossover. MML Plumbing: Read the full case study →

Hidden Heating Leak Traced Beneath the Floor in NW3
A heating system in Hollycroft Avenue, NW3, was repeatedly losing pressure with no visible leak; thermal imaging and hydrogen tracer gas testing produced readings of approximately 1,000 ppm, narrowing the suspected leak to concealed pipework near the plant room and bathroom.
Still bleeding and topping up? Book your leak investigation today
If you’re bleeding radiators or topping up the pressure again and again, the “air” may be a leak in disguise. Every week it runs, more water goes into the building, and a simple maintenance job turns into a repair bill.
MML Plumbing will find out whether it’s air or a leak and, if it’s a leak, show you exactly where it is.
- 15+ years finding hidden heating leaks across London and North London
- Fully insured and 5-star rated
- Written, insurance-ready report for your trace and access claim
How it works:
- Book your survey. Call or send the form, and we’ll confirm a time that suits you.
- We find the answer. We confirm whether the system is losing water, isolate the circuits and pinpoint the source with thermal imaging, acoustic detection and tracer gas.
- You get it in writing. The report shows the exact location, the evidence and the next steps, ready for your insurer.
No guesswork and no lifting whole floors. We only open the one spot the evidence points to.