What does pressure testing establish?
- Whether the loss is real, or just trapped air or a gauge reading on a hot system
- Whether the boiler or the pipework is losing water
- Which circuit or run is leaking, and which ones are sound
- How fast the loss is, which tells us the likely size of the leak
- Whether it leaks hot, cold or both, which points to the type of fault
- A before-and-after record for your insurance report

What does pressure testing actually involve?
It means sealing off part or all of the heating system, bringing it to a set pressure and watching whether it holds.
A healthy sealed section will hold that pressure. One with a leak will drop, and how quickly it drops tells us about the size of the fault. We use our own test gauge rather than relying on the boiler pressure gauge alone. The gauge on most modern boilers is designed to show roughly whether the system pressure is in the right zone, not to measure small losses precisely.
We then close valves to split the system into sections and test each in turn:
- The boiler, isolated from the pipework using the valves underneath it
- The heating flow and return leaving the boiler
- Individual runs, such as upstairs and downstairs
- The hot water cylinder coil on a system boiler
- Extensions, outbuildings or underfloor heating on their own circuits
If one section holds and another doesn’t, we’ve found where the water is leaving without looking at a single hidden pipe.
How does it tell a real leak from something else?
By removing the doubt that trips people up. A falling gauge could mean three different things:
- Trapped air. If you’ve recently bled radiators, the pressure falls once as water replaces the air. Under a sealed test with no air being added, air-related drops stop. A true leak keeps falling.
- A hot reading. When water expands with heat, pressure rises. A reading taken hot and compared with one taken cold can look like a loss that isn’t there. We test at a stable temperature.
- A real leak. The pressure keeps dropping under controlled conditions, with every valve accounted for. Once the losing section has been identified, thermal imaging leak detection and, where required, hydrogen tracer gas leak detection can help narrow down the concealed source.
Can pressure testing tell the boiler from the pipework?
Yes, and this is one of the most useful things it does.
By isolating the boiler from the rest of the system, we can test each side separately. If the pipework holds and the loss is on the boiler side, the cause is usually one of these:
- A faulty pressure relief valve, the boiler’s safety device, releasing water through the small copper pipe on the outside wall. You may see a visible drip or water dripping below it.
- The expansion vessel. If it has lost its air charge, pressure rises too high when hot, the relief valve opens, and the pressure falls again as it cools.
- The boiler’s filling loop passing water, which usually makes pressure rise rather than fall.
- An automatic air vent weeping at the top of the system.
- A faulty component inside the boiler casing, such as the heat exchanger or circulation pump seals.
Those are boiler repairs, and they aren’t MML Plumbing’s work. If the pipework is the part that won’t hold, that’s a hidden leak, and finding it is exactly what we do. Pressure testing draws that line cleanly, so you call the right people the first time.

What can the rate of loss tell you?
A lot. From the tests we run:
- A fast drop points to a larger failure, often a split or a joint that has let go. It’s worth checking ceilings and floors for signs now.
- A slow, steady drop is typical of a pinhole leak in copper pipe. These rarely show damp patches because the water dries out or soaks into a void before it reaches a surface.
- A drop only when hot suggests a joint or fitting that opens up as the pipework expands, or a boiler-side expansion problem.
- A drop only when cold can point to a joint that seals when warm and weeps when it contracts.
That’s why we sometimes test the same section both hot and cold. If your boiler shows low pressure every morning after the heating has been off overnight, that’s one of the clearest signs of a leak losing water around the clock, regardless of the water pressure it had the evening before. The pattern narrows down not just where the leak is, but what kind of fault it’s likely to be.
Will pressure testing find the exact spot?
Not by itself. It narrows the search; it doesn’t pinpoint the leak.
A pressure test will tell us the ground floor heating run is losing water while everything else holds. That’s a huge step. But it won’t tell us the leak is half a metre under the hall floor. On the run it has identified, the other methods take over:
- Thermal imaging traces the run and shows where escaping water disturbs the heat pattern.
- Moisture mapping confirms where water has gathered in the fabric.
- Acoustic detection listens for water escaping under pressure.
- Hydrogen tracer gas pinpoints the exact point of failure.
Pressure testing decides where to look. The other methods decide exactly where to open.
Is pressure testing safe for my boiler and radiators?
Yes. Every test is carried out within the safe working limits of your boiler system, following the boiler manufacturer’s guidance on maximum pressure. The pressure relief valve stays in place as a safety measure throughout. We never put too much pressure on a system to “force” a leak to show.
On a combi boiler or a system boiler, the test puts no more strain on radiators, each radiator valve or the heating circuit than normal running does. Sealed systems are designed to hold pressure, and the test simply checks that yours does.
What if the test shows no loss at all?
That’s a useful result too. If every section holds, the system isn’t leaking, and the earlier pressure drops had another explanation. From the jobs we attend, it’s usually one of these:
- Air after bleeding radiators, which causes a single drop
- Readings compared hot and cold, where normal pressure changes look like a loss
- A boiler-side fault that only shows under certain conditions, such as when the heating water gets very hot
We’ll explain what we think happened and what to watch for. If the boiler’s pressure drops again later, the test results give a baseline to compare against.
Can I pressure test my system myself?
You can do a simple version that tells you whether it’s worth calling someone:
- With the system cold, top up to 1.5 bar or the figure in your boiler’s manual.
- Close the filling loop fully.
- Write down the boiler pressure gauge reading each morning, before the heating comes on, for five days.
If the boiler pressure is low again after a few days and there’s nothing dripping outside or on the visible pipework, the system is losing water. Topping up may fix low boiler pressure for a day, but it won’t fix the leak. What a DIY check can’t do is isolate sections or separate the boiler from the pipework. That needs valves closed in the right order, a proper test gauge and time.
One word of caution: avoid adding a leak sealer to the system before it’s been tested. In our experience, it can make a small leak temporarily harder to detect, while the underlying cause is still there.
Why is pressure testing the right place to start?
Because a sealed central heating system holds very little spare water, and the leaks that cause a boiler to lose pressure rarely show themselves. When a boiler keeps losing pressure with no obvious central heating fault, the water is usually leaving the pipework. We usually find central heating leaks beneath suspended floors, cast into screed, inside walls, or buried underground. You may hear water flowing when nothing should be running, but there’s usually nothing to see.
Without pressure testing first, the search covers the whole house. With it, the search covers one run. Where a concealed void needs closer inspection, borescope leak detection can help inspect otherwise hidden areas through suitable access points. That’s the difference between one small opening and several.
What will you get from an MML Plumbing pressure test?
A clear answer about whether your system is losing water, which part is responsible, and what happens next. If the loss is on the pipework, we carry on and find the leak. If it’s on the boiler side, we’ll tell you which part, so you don’t pay for a search you don’t need.
MML Plumbing works across London and North London. We’re fully insured and 5-star rated, and every survey ends with a written, insurance-ready report recording each test, the readings and the findings. That’s the evidence your insurer will want for a trace and access claim.
Related questions
- How do I know whether pressure loss is coming from the boiler or the heating pipes?
- What could cause boiler pressure to fall overnight while the heating is off?
- What does it mean if boiler pressure falls only while the heating is running?
- Could a small radiator leak be causing repeated boiler pressure loss?
- Can more leaks cause boiler pressure issues?

Real Leak Detection Examples From North London Homes
Real Investigations from the Field
This section features real boiler pressure loss and hidden heating leak investigations carried out by MML Plumbing across London. Each case shows the symptoms reported, the testing methods used, the evidence found and the confirmed cause of the problem.
These real-world investigations demonstrate how pressure loss and concealed heating leaks are investigated in practice, using evidence to narrow down the source before unnecessary repairs or destructive access are considered.

Boiler Losing Pressure – Two Hidden Heating Leaks Found
A North London homeowner’s boiler was losing pressure rapidly, dropping by around 1 bar in under 10 minutes; our leak detection investigation identified two concealed pipe leaks beneath tiled and concrete floors, which were located, repaired and pressure-tested until the system remained stable. Read the full case study →

Boiler Losing Pressure – Multiple Hidden Faults Found in SW19
A large heating system in SW19 was losing around 3 litres of water per day with no obvious leak; our investigation identified multiple sources of pressure loss, including radiator and air-vent leaks, plus evidence of an internal heating-to-hot-water crossover. MML Plumbing: Read the full case study →

Hidden Heating Leak Traced Beneath the Floor in NW3
A heating system in Hollycroft Avenue, NW3, was repeatedly losing pressure with no visible leak; thermal imaging and hydrogen tracer gas testing produced readings of approximately 1,000 ppm, narrowing the suspected leak to concealed pipework near the plant room and bathroom.
Leak “could be anywhere”? Let’s narrow it to one run
If your boiler is losing pressure, the pressure drops every few days, and nobody can say where the water’s going, a proper pressure test is the fastest way to a real answer. Every week it runs, more water goes into floors and walls, and topping up only hides it.
MML Plumbing will prove the loss, isolate the run and find the leak before any floor is opened.
- Boiler and pipework tested separately, so you know exactly who you need
- Each circuit isolated, narrowing the search to one run
- The leak pinpointed with thermal imaging, acoustic detection and tracer gas
- A written, insurance-ready report with every reading
- Fully insured and 5-star rated, across London and North London
How to book:
- Call or send the form. Tell us how often you top up and how fast the pressure falls.
- We test and isolate. We confirm the loss and find the run that won’t hold.
- We pinpoint and report, so you know exactly where the leak is and what to fix.