How can there be more than one leak at once?
Because the causes of leaks are rarely confined to one point.
If copper pipe is corroding from the inside, through age, water chemistry or years of fresh heating water brought in by topping up, that’s happening across the whole central heating pipework. The first leak is simply the pipe that failed first. It isn’t the only one that’s thinning.
So on a system that has been losing pressure for a long time, two or three weak points can be at different stages of failing at once. The one losing the most water dominates the gauge. The others contribute quietly in the background, until the main one is gone.
Why does one leak hide another?
Because the pressure gauge only shows the total loss, not how many places it’s coming from.
A larger leak loses enough water that a slower weep alongside it goes unnoticed. Fix the big one and the pressure improves noticeably, so everyone assumes the job is done. But the smaller leak is still there. With the main loss gone, it becomes the reason the gauge drops again.
We’ve seen this play out. A homeowner’s leak is repaired; the system is better for a few weeks, then a slow drop returns, and they think the repair failed. Often it didn’t. A second leak has simply come out from behind the first.

What are the signs you may have more than one leak?
From the jobs we attend, these patterns suggest there’s more than one source:
- The pressure improved after a repair but still falls, just more slowly
- The rate of loss changed without anything being repaired, as a second weep opened up
- Damp patches or staining in two separate areas of the house
- The pressure falls both overnight and when hot, in a way that doesn’t fit a single cause
- A persistent drop with a known boiler-side fault, such as a drip from the pipe on the outside wall, that continues after the boiler is repaired
- Faint green staining on more than one exposed copper pipe or radiator valve, which can be a sign of old weeps
Can a leak and a boiler fault happen at the same time?
Yes, and it’s one of the most confusing combinations. The ones we see most:
- A pipework leak plus a worn relief valve. Repeated overfilling to keep up with a leak makes the safety valve open again and again, until it stops resealing. Now there’s excess water escaping outside and a leak under the floor.
- A pipework leak plus a faulty expansion vessel. When water expands as it heats, the vessel should take up the extra water volume. If it can’t, pressure changes get more extreme, masking how much the leak itself is losing.
- A pipework leak plus a faulty heat exchanger. An internal leak inside the boiler casing and a hidden leak on the pipes can both pull the gauge down.
- A leak on the hot water cylinder coil alongside a pipework leak on a system boiler.
Boiler-side repairs aren’t MML Plumbing’s work. What we can do is show clearly how much of the loss is on the pipework, so nothing is missed.

What should you rule out before assuming a second leak?
Not every drop after a repair means another leak. Before booking, rule out three things:
- Air from the repair. Most repairs mean draining and refilling part of the system. That brings in air, and bleeding the radiators afterwards will drop the pressure once. Re-pressurise once, and it should hold.
- The filling loop. Check that it was fully closed after the repair. A loop left slightly open can make readings rise and fall unpredictably.
- The pressure relief valve. If the system was overfilled after the repair, the relief valve may have opened as the water volume increases with heat. Check the pipe on the outside wall for a drip.
If all three are clear and the system pressure still falls, the loss is real, and there’s likely water leaking somewhere else.
Does a second leak mean the first repair was poor?
Usually not. It’s worth checking, though, because the answer changes who should put it right.
A problem with the repair itself tends to show quickly, within hours or a day, and right beside the new work. A second, separate leak tends to show as a slow, steady drop that starts once the system has settled, and it can be anywhere on the system.
When we investigate, we isolate and test the repaired section on its own first. If it holds, the repair is cleared, and we can show exactly where the remaining pressure loss is coming from.
How do you make sure you’ve found them all?
By not stopping at the first one. That’s the discipline that matters here.
- We test each run independently. When we isolate the heating system section by section, we check whether every run holds pressure, not just the one we suspect.
- We keep going after the first find. If one run is losing water, we still verify the others.
- We compare the rate of loss. If one leak can’t explain how much water the system is losing, there’s likely another.
- We re-test after repair. Once a leak is fixed, testing the whole system under pressure confirms it now holds properly, not just better than before.
How can you tell after a repair whether there’s another leak?
Keep a simple record:
- Before the repair, note how many days it takes for the pressure to drop from 1.5 bar to around 1 bar.
- After the repair, re-pressurise to 1.5 bar with the system cold and time it again.
- If the pressure now holds for weeks, the repair solved it.
- If it still drops, but more slowly, there’s a good chance a second leak is involved.
A healthy sealed system should hold its pressure. Any gauge drop that keeps returning after a repair is worth investigating properly rather than topping up.
How does the investigation find more than one leak?
We isolate the sealed central heating system into sections and test each one, noting which runs are losing water. Then, on each losing run:
- Thermal imaging traces the pipe and shows each leak as a soft, cool bloom off a warm line.
- Moisture mapping confirms where water has gathered.
- Acoustic detection listens for water escaping under pressure.
- Hydrogen tracer gas fixes each exact point.
Each leak gets its own confirmation. We only mark a spot when the methods agree on it, so every opening is small and justified. You can read more about how MML Plumbing finds hidden leaks.
Where do multiple leaks tend to sit?
On the concealed runs, and often clustered where the system is weakest. On the properties we survey, that’s usually:
- older sections of copper pipe most prone to corrosion
- under suspended floors, on runs laid at the same time
- in screed, where copper meets concrete
- inside walls, on drops feeding several radiators
A sealed system holds very little water, so even a small leak pulls the pressure down within days. Two small radiator leaks together pull it down faster, and neither may leave a single damp patch.


Is it safe to keep running the heating in the meantime?
For you, yes. Most modern boilers have a safety lockout that shuts them down when the pressure falls into the red zone, so low pressure won’t put you at risk.
The risk is to your home. Many homeowners keep topping up for months, not realising how much pressure, and how much water, they’re replacing. With two water leaks, the loss is faster, and both are feeding water into floors and walls. It’s worth getting them found before the damage spreads.
How can you reduce the chance of more leaks?
Once the leaks are found and repaired:
- Stop repeated topping up. Each top-up adds oxygen that speeds up corrosion.
- Ask about cleaning and an inhibitor for the system to slow internal corrosion.
- Watch the gauge for a few weeks after the repair, so any new loss is caught early.
- Deal with boiler-side faults promptly. A relief valve or expansion vessel that isn’t working properly causes pressure swings that put extra strain on old joints.
- Keep your records. A log of readings and top-ups makes it much quicker to spot and find anything new.
Related questions
- Why does my boiler pressure keep dropping after a recent repair?
- Can an older heating system be more likely to develop hidden leaks?
- What happens if no leak is found during the first investigation?
- Why is my underfloor heating losing pressure?
- Does a pressure drop stop my radiators from heating properly?
Real Leak Detection Examples From North London Homes
Pressure still dropping after a repair? Let’s find every leak
If your boiler pressure improved after a repair but still won’t hold, there may be a second leak the first one was hiding. Topping up keeps it going, but it also adds to the corrosion that causes more leaks.
MML Plumbing will test every circuit, find each source and confirm the system holds, so nothing is left behind.
- Every run tested separately, not just the obvious one
- Each leak pinpointed with thermal imaging, acoustic detection and tracer gas
- Small, targeted openings, only where the evidence agrees
- A written, insurance-ready report covering every leak found
- Fully insured and 5-star rated, across London and North London
How to book:
- Call or send the form. Tell us about any previous repairs and how fast the pressure drops now.
- We test the whole system, isolating each run and pinpointing every leak.
- You get the full picture in writing, so the repairs fix the problem for good.

Real Investigations from the Field
This section features real boiler pressure loss and hidden heating leak investigations carried out by MML Plumbing across London. Each case shows the symptoms reported, the testing methods used, the evidence found and the confirmed cause of the problem.
These real-world investigations demonstrate how pressure loss and concealed heating leaks are investigated in practice, using evidence to narrow down the source before unnecessary repairs or destructive access are considered.

Boiler Losing Pressure – Two Hidden Heating Leaks Found
A North London homeowner’s boiler was losing pressure rapidly, dropping by around 1 bar in under 10 minutes; our leak detection investigation identified two concealed pipe leaks beneath tiled and concrete floors, which were located, repaired and pressure-tested until the system remained stable. Read the full case study →

Boiler Losing Pressure – Multiple Hidden Faults Found in SW19
A large heating system in SW19 was losing around 3 litres of water per day with no obvious leak; our investigation identified multiple sources of pressure loss, including radiator and air-vent leaks, plus evidence of an internal heating-to-hot-water crossover. MML Plumbing: Read the full case study →

Hidden Heating Leak Traced Beneath the Floor in NW3
A heating system in Hollycroft Avenue, NW3, was repeatedly losing pressure with no visible leak; thermal imaging and hydrogen tracer gas testing produced readings of approximately 1,000 ppm, narrowing the suspected leak to concealed pipework near the plant room and bathroom.